Dashboards End-of-Line

| What?

Microplan's DB-EOL test rigs are suitable for dashboards of:

  • boilers
  • water heaters

| How?

DB-EOL test rigs are intended to perform full functional tests and wirings check.

| Where?

In the production line before the final assembly.

| Who?

Manufactures of:

  • boilers
  • water heaters
  • control boards

| Why?

  • Reduction of final test time
  • Reduced faults at final tests
  • Takt time balance [learn more on our blog]
  • Quality improvement
  • Full traceability of test data 
  • Human operations driven and controlled by the test rig
  • Test data available for statistical elaborations
  • Market credibility

| Tests

  • Operator identification through scanner or badge
  • Dashbioard identification through barcode reading and test sequence automatic loading and running
  • Ground wiring check of circulator, fan, gas valve drivers, chassis, moisture sensor
  • NTC simulation
  • 3-way valve check on CH and DHW
  • Check/measurement of modulating fan command
  • Check/measurement of gas valve modulating command
  • Check/measurement of spark discharge voltage
  • Flame simulation
  • Pressure switches simulation
  • Flow switches simulation
  • Pump electric wiring check
  • Moisture sensor simulation
  • Faults conditions simulation and check of lockout state 