Executing tests according to international standards and R&D free tests

Measurement accuracy and results repeatibility are critical to the laboratory and R&D tests: this is what Microplan laboratory test benches are designed for. The same hardware platform can run several software packages which are based on the applicable international standards of the sector. Tests are run automatically and a test report is automatically produced at the end, while a log function is always available for further needs. R&D free tests are also possible being a synoptic panel available to the operator to execute customised tests by means of keyboard and mouse while having the test evolution under control with a graph.

  • ERP6.2 for boilers with power range 1-10 kW
  • ERP1.2 for boilers with power range 1-70 kW
  • ERP5.2 for boilers with power range 1-120 kW
  • ERP2.2 for boilers with power range 2.5-250 kW
  • ERP3.2 for boilers with power range 20-400 kW
  • ERP7.2 for boilers with power range 80-1000 kW
  • ERP4.2 for boilers with power range 20-2000 kW

Functions overview

There are two main categories of use:

  • automatic execution of tests according to the standards;
  • interactive use for free R&D tests.

Automatic execution mode
In this mode, the tests are pre-defined in the software according to the standards, but some freedom is left to the user, who can set some parameters of the tests according to his preferences.
In order to run a certain test, the operator selects it from a menu: an Editor panel appears on the screen about the selected test. The operator can confirm or adjust a list of parameters in that panel.

R&D interactive use
This feature gives the user a set of powerful tools for free tests. In short, the operator can manage every resource of the bench working with mouse and keyboard on a Synoptic graphic diagram showing the bench circuits. It includes active elements (valves, switches, proportional/modulating valves etc.) that the operator can control.


Software packages

Different software packages can run on the same test bench. The ones listed hereafter are about European and North American standards.

a) tests of gas boilers and gas water heaters according to European ERP regulation - Chinese standard GB25034

b) tests of DHW circuit of gas appliances according to EN13203

c) tests of gas water heaters according to EN26 - GB6932 - CJ/T 395 - AS5263

d) tests of gas water heaters according to e-CFR Title 10, Chapter II, Subchapter D, Part 430, Subpart B, Appendix E: 2018;

e) tests on gas water heaters according to ANSI Z21.10.3 – CSA 4.3; g) tests on gas boilers according to ASHRAE 103 (“AFUE”).


Installation requirements:

  • gas
  • compressed air
  • water
  • cooling water
  • electricity
  • water drains

  • ERP6.2 for boilers with power range 1-10 kW
  • ERP1.2 for boilers with power range 1-70 kW
  • ERP5.2 for boilers with power range 1-120 kW
  • ERP2.2 for boilers with power range 2.5-250 kW
  • ERP3.2 for boilers with power range 20-400 kW
  • ERP7.2 for boilers with power range 80-1000 kW
  • ERP4.2 for boilers with power range 20-2000 kW

Functions overview

There are two main categories of use:

  • automatic execution of tests according to the standards;
  • interactive use for free R&D tests.

Automatic execution mode
In this mode, the tests are pre-defined in the software according to the standards, but some freedom is left to the user, who can set some parameters of the tests according to his preferences.
In order to run a certain test, the operator selects it from a menu: an Editor panel appears on the screen about the selected test. The operator can confirm or adjust a list of parameters in that panel.

R&D interactive use
This feature gives the user a set of powerful tools for free tests. In short, the operator can manage every resource of the bench working with mouse and keyboard on a Synoptic graphic diagram showing the bench circuits. It includes active elements (valves, switches, proportional/modulating valves etc.) that the operator can control.


Software packages

Different software packages can run on the same test bench. The ones listed hereafter are about European and North American standards.

a) tests of gas boilers and gas water heaters according to European ERP regulation - Chinese standard GB25034

b) tests of DHW circuit of gas appliances according to EN13203

c) tests of gas water heaters according to EN26 - GB6932 - CJ/T 395 - AS5263

d) tests of gas water heaters according to e-CFR Title 10, Chapter II, Subchapter D, Part 430, Subpart B, Appendix E: 2018;

e) tests on gas water heaters according to ANSI Z21.10.3 – CSA 4.3; g) tests on gas boilers according to ASHRAE 103 (“AFUE”).


Installation requirements:

  • gas
  • compressed air
  • water
  • cooling water
  • electricity
  • water drains

Contact Us

Contact us for more informations about this product. We’ll answer you as soon as possibile!



Microplan test benches installed in the world

Every day Microplan tests systems are switched on in

150 plants of